Thermocouple and ionization ring temperature range. The automatic pensky martens closedcup tester measures the flash point at the lowest temperature at which the application of an ignition source causes the vapors of a sample to ignite. The automated pensky martens flash point analyzer represents a perfect union of nextgeneration technology with traditional robust quality. Green berets ultralight bug out bag with gear recommendations duration. To determine the flash and fire point of given sample of heavy oil. Astm d93 19 standard test methods for flash point by pensky. All you do is insert the appropriate test module in the instrument and press start. Astm d93 flash point tests by penskymartens closed cup. Open and closed cup flash point what is the difference. See test apparatus apparatus design features, 2627 arnoboldis tester, 73 asphalts, 63 astm committee d01 on paint and related coatings, 51, 5455, 63, 6869 astm committee d02 on petroleum products and lubricants, 711, 19, 36, 51, 63, 68, 69, 8588 astm committee e27 on hazard potential of chemicals, 53, 64. Includes adjustable support bracket and mounting rod. Note 1flash point determination as above 250c can be performed, however, the precisions have not. Ordering information hfp 339 pensky martens flash point analyzer is a compact and selfcontained instrument for precise flash point determination.
Oil and petroleum testing instruments pensky marten. Temperature measurement intelligent pt 100 probe with built in calibration, 10 calibration points. Penskymartens closed cup automatic flash point tester. The system software runs on an integrated processor pc running the latest windows operating system. Pensky marten flash point apparatus pmfpa ask for price this apparatus is made as per ip 34, astmd93 and is 1448 part i 1270 p. Basics of penskymartens closedcup flash point testing anton. Mar, 2020 according to astm d9319, penskymartens test procedures can determine the flash point of petroleum products in the 40c to 370c range by either manual or automated closedcup apparatus, as well as determining the flash point of biodiesel in the 60c to 190c range by an automated closedcup apparatus. Pensky martens apparatus pensky martens flash point. Penskymartens flash point astm d93 ip 34 stanhopeseta. In addition to standard test methods, the hfp 339 may be programmed with userdefined. For determining the flash point of fuel oils and lubricating oil, bitumen other than cutback bitumen and suspension ofsolids in liquids, having a flash point above 49c. The sample is heated and stirred at specified rates depending on the material that is being tested. Fire detection in extended range around test cup and flash detection outside the cup.
The flash and fire point temperatures may differs by 20c to 60c when it is tested by open cup apparatus. College of engineering, organized by coanchor institute ldce. Penskymartin apparatus, thermometer, spirit lamp, splinters and oil. The lid is sealed and the ignition source is introduced into the vessel itself, allowing for a closer approximation to reallife conditions such as those found inside a fuel tank. Particular care should be taken to avoid the presence of any gasoline or naptha used to clean the apparatus after a previous test. Read on to learn about the basics of penskymartens closedcup flash point testing. Again, as the name suggests, the flash point in the closed cup method is conducted inside a closed vessel which is not open to the outside atmosphere. Astm d93 test methods provide the only closed cup flash point test procedures for temperatures up to 370c or 698f. The oil cup is made of brass, fitted with a thermally insulated lifting handle. The temperature of the approximately 70 ml test specimen is increased rapidly at first and then at a slower constant rate as the flash point is approached. Semiautomatic pensky marten flash point apparatus flash point is lowest temperature at which application of the ignition source causes the vapour of a specimen of the sample to ignite under the specified condition of the test. Read this manual thoroughly before use, and keep it for later use.
The apparatus is widely used for determination for closed cup flash point of fuel oil, cut back asphalts, other viscous material and suspension of solids having a flash point above 49oc 120 of. Laboratory hzbs3 oil tester penskymartens closed cup flash. Pensky marten apparatus thermodynamics chemistry scribd. Pensky martens flash point apparatus with voltage varic control oil test jet. Basics of penskymartens closedcup flash point testing the flash point is essentially the lowest temperature of the liquid or semisolid at which vapors from a test portion combine with air to give a flammable mixture and flash when an ignition source is applied.
Practical manual shri ramdeobaba college of engineering. This apparatus is made as per ip 34, astmd93 and is 1448 part 1 1270 p. Ordering information hfp 36x series base unit hfp 360 penskymartens flash. You have clicked a page that seems to be very popular. Pm93 penskymartens flash point tester stanhopeseta. Pensky martens closed cup automatic flash point tester model apm7 maintenance manual ver 2.
Alibaba manufacturer directory suppliers, manufacturers. Flash and fire point of lubricating oil is determined by pensky martens apparatus which consists of following parts. Manual pensky martens closed cup flash point tester k162xx this certificate verifies that part number k162xx, manual pensky martens closed cup flash point tester, was manufactured in conformance with the applicable standards set forth in this certification. Stirrer motor, 115v 60hz 1 slow speed gear motor rotates stirrer of pensky martens tester at 115rpm for procedure a and at 250rpm for procedure b. The methods cover the determination of the flash point of petroleum products in the temperature range from 40 to 370c, and of biodiesel by an automated penskymartens closed cup apparatus in the temperature range of 60 to 190c. Pensky martens digital flash tester 81b05a pensky martens accessories supplied with the instrument. Siddonsmartin emergency group protecting the southwest. Koehler instrument flash point cup for pensky martens closed tester flash point test cup spectrophotometers, refractometers and benchtop instruments. To determine the flash and fire point temperatures of the given sample of oil kerosene using pensky martens closed cup apparatus. K16225 stirrer motor, 115230v 5060hz slow speed gear motor rotates stirrer of pensky martens tester at 105rpm for procedure a and at 250rpm for procedure b. Automated pensky martens flash point analyzer optiflash flash point measuring range 30oc to 400oc heating system heater band for uniform heating of the heater block, test method or userde.
For flash point determinations of liquids with a viscosity of below 5. Particular care should be taken to avoid the presence of any gasoline or naptha used to clean the apparatus. Hi, i am mohan dangi welcome to our youtube channel digitech education about video. This international standard describes three procedures, a, b and c, using the penskymartens closed cup tester, for determining the flash point of combustible liquids, liquids with suspended solids, liquids that tend to form a surface film under the test conditions, biodiesel and other liquids in the temperature range of 40 c to 370 c. Pensky martens flash point is automatically simple, userfriendly determined in. Hfpseries automatic flash point analyzers are designed to simplify the testing of hydrocarbon samples using the pensky martens or other closed cup test methods. Determines flash points of a wide range of products by a closed cup method with two option speed stirring of the sample. Makes penskymartens, tag, and abel flash point testing. Manufacturer of flash point apparatus abel flash point instrument, pensky martin closed cup flash point instrument, coc cleveland open cup flash point tester offered by acute instruments private limited, navi mumbai, maharashtra. Koehler instrument flash point cup for pensky martens closed tester heatresistant handle.
This test method cover the determination of the flash point of petroleum products in the temperature range from 40 to 360c by a manual penskymartens closedcup apparatus or an automated penskymartens closedcup apparatus, and the determination of the flash point of biodiesel in the temperature range of 60 to 190c by an automated pensky. Spring operated rotating shutter having piolet jet. A brass test cup is filled with a test specimen and closed with a lid, through which an ignition source can be introduced periodically. Kg ludwigerhardring 15827 dahlewitz germany tel fax. Penskymartens digital tester, bitumen testing equipment. The main components of the pensky martens flash point apparatus are follows.
Pensky martens flash point apparatus with voltage variac, electronic digital temperature indicator and constant speed stirring device oil test jet. Pensky marten flash point apparatus, pensky marten flash. The pensky martens test is a closedcup method as opposed to the cleveland opencup method. Siddons martin emergency group is the regions preeminent leader in emergency vehicle sales, parts, and service. However, a greater difference may be obtained if some additives are mixed with oil. Flashpoint with closed cup penskymartens method pma 4. We offer a stellar lineup of new ambulances, brush trucks, pumpers, ladders, platforms, tankers, rescues, command, and specialty apparatus from pierce manufacturing, skeeter brush trucks, braun industries, crestline coach products.
Flash point apparatus pensky martin flash point apparatus. In addition to performing standard pensky martens astm d 93, tag astm d 56, and abel ip 170. Product description the koehler k7 automatic pensky martens closed cup flash point analyzer is for flash point determination of biodiesel, distillate fuels, new lubricating oils, residual fuel oils, cutback residua, used lubricating oils, mixtures of petroleum liquids with solids, petroleum liquids that tend to form a surface film during testing. The automatic closed cup flash point tester autoflash93 detects the flash point. Pensky martin flash point apparatus is widely used for. Consult pacs hfp 339 automatic closed cup penskymartens flash.
Pensky martens flash point apparatus with voltage varic with geared electric motor stirrer 120 r. Basics of penskymartens closedcup flash point testing. Koehler instrument flash point cup for penskymartens. The apparatus consists of brass test cup with handle removable cup cover with spring. Flash and fire point pensky martens closed cup apparatus conduct an experiment to determine the flash point and fire point of a given oil using pensky martens closed cup apparatus aim. Pensky martens closed cup automatic flash point tester model apm7 with data memory instruction manual rev. Pensky marten flash point apparatus is designed as per is 12091978. Basics of pensky martens closedcup flash point testing the flash point is essentially the lowest temperature of the liquid or semisolid at which vapors from a test portion combine with air to give a flammable mixture and flash when an ignition source is applied. Flash point by automatic penskymartens closed tester. Pensky martin experiment procedure tutorial by students of nbkrist. The pensky marten flash point apparatus is made as per ip 34. The cup lid, with insulated handle, is fitted with two opposite wedge cams, which engage under. Electric pensky martens tester k16200 astm d93 and api 510 instructions for use thoroughly clean and dry all parts of the cup and its accessories before starting the test. Pma 5 is suitable for flammability applications on both biodiesel and biodieselblended fuels along with distillate fuels like diesel, heating oil, and kerosene.
Standard test methods for flash point by penskymartens. Practical manual shri ramdeobaba college of engineering and. Penskymartens flash point apparatus alcon scientific. Koehler instrument flash point cup for penskymartens closed. Included is a user friendly manual machine interface, electric standard or gas optional ignition and thermal detection. Flash point tester automated abel flash point tester. Penskymartens closed cup automatic flash point tester model. Hamco 30d automatic pensky martene flash point apparatus. This manual contains important technical information as wall as safety information. Innovative instrument design for improved ease of use and easy cleaning. In accordance to astm d93 procedure a, b and c stirring rate. Pensky martens flash point testers aim to simulate the situation of a liquid spill in a closed environment, giving a realistic and safe flash point. Pensky martens flash point is automatically determined in strict compliance with the appropriate test method.